Ionizing Radiation
Online ISSN : 2758-9064
Quick and High Position Resolution Measurement of Neutron Flux Distribution by Use of Optical Fiber with Scintillator
Chizuo MoriKatsuo YanagidaTaichi Osada
Author information
JOURNAL FREE ACCESS

1995 Volume 21 Issue 3 Pages 79-84

Details
Abstract

  A new measurement method for neutron flux distribution was developed, which made it possible to measure the distribution very quickly and with high position resolution by use of optical fiber whose tip was painted with a mixture of ZnS(Ag) scintillator and LiF. Position resolution is about 1mm. In Kyoto University Critical Assembly, it was possible to measure thermal neutron flux distribution in several minutes over 100cm. The method can be applicable for the measurement of fast neutrons and γ-rays.

Content from these authors
© 1995 The author(s)
Previous article Next article
feedback
Top