圧力技術
Online ISSN : 1347-9598
Print ISSN : 0387-0154
ISSN-L : 0387-0154
論文
サイトスペシフィック地震動を用いた大型液化水素貯槽の非線形時刻歴応答解析
平底円筒型液化水素貯槽の地震時応答解析と破壊力学評価:(第1報)
田附 英幸堀野 聡前田 敬一郎川畑 友弥
著者情報
ジャーナル フリー

2026 年 64 巻 2 号 p. 34-41

詳細
抄録
Flat-bottom cylindrical tanks are anticipated for future large-scale liquefied hydrogen (LH2) storage. However, since no such tanks exist for LH2 service, confirming their response during major earthquakes is critical. This study investigates the seismic behavior of a 50,000m³ LH2 tank using 3D nonlinear time-history response analyses, considering elasto-plastic material effects and lateral sliding at the base. Two ground motions were evaluated: a site-specific wave and a more severe wave fitted to the KHKS Level 2 design spectrum.
The site-specific motion resulted in a small response due to the soil's non-linear dampening. In contrast, the spectrum-fitted wave induced a significantly larger response, causing substantial lateral sliding and high stress concentration at the corner joint of the annular plate. While stresses in the main shell remained low, the corner joint is identified as a critical area, highlighting the need for detailed fracture evaluation.
著者関連情報
© 2026 一般社団法人 日本高圧力技術協会
次の記事
feedback
Top