電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
論文
新幹線切替セクションにおける無負荷投入過電圧とサージ伝搬
林屋 均安喰 浩司
著者情報
ジャーナル フリー

2006 年 126 巻 3 号 p. 322-329

詳細
抄録
In some substations and sectioning posts of Shinkansen power system in JR East area, the electrical transient phenomena when the Shinkansen train passes through the changeover section are reported during the last a few years. In this paper, the closing surge phenomena of the Shinkansen changeover section are elucidated based on both the detail measurement of the surge phenomena at substations and computer simulation. It is clarified that the surge propagation and the reflection at open end of the contact wire system cause the over-voltage at changeover section and result in the discharge of the lightning arresters at some substations.