電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
論文
MTS法に基づく配電盤余寿命推定手法の評価
高木 義之犬島 浩松本 正昭
著者情報
ジャーナル フリー

2006 年 126 巻 6 号 p. 804-811

詳細
抄録
Most switchboards are used for a long term of about 30 years. As for the switchboard, the situation of the use and maintenance is individually and greatly different. So the life-expectancy presumption technique of the switchboards has not been established. We executed the deterioration diagnosis for the switchboards that had been used for 30 years. We paid attention to the surface deterioration of the insulation materials that is the main element that decides the life-expectancy of the switchboards. We evaluated the life-expectancy presumtion technique of aged switchboards based on MTS (Mahalanobis Taguchi system) method. This technique attracts attention in recent years. And we confirmed the presumption result was corresponding to the result of the verification with temperature controlled bath actually.
著者関連情報
© 電気学会 2006
前の記事 次の記事
feedback
Top