電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
研究開発レター
PLL 回路を用いた単相回路における簡易な有効・無効電流検出法
大村 泰平木 英治田中 俊彦
著者情報
ジャーナル フリー

2007 年 127 巻 5 号 p. 538-539

詳細
抄録
This paper proposes a novel detection method of active and reactive currents in single-phase circuits. This method uses only two multipliers and LPFs for detecting active and reactive currents with a PLL circuit. In the proposed method the fundamental active-reactive component in single-phase circuits can be detected by LPFs in the time domain like the instantaneous active-reactive power theory in three-phase circuits. The basic principle of the proposed detection method is discussed in detail, and then confirmed by digital computer simulation. Digital computer simulation results demonstrate that the proposed method can detect the active-reactive current in single-phase circuits in the time domain.
著者関連情報
© 電気学会 2007
前の記事 次の記事
feedback