電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
論文
マトリックスコンバータを用いた電力障害補償の提案
玉田 俊介伊東 淳一
著者情報
ジャーナル フリー

2008 年 128 巻 7 号 p. 933-939

詳細
抄録

Recently, renewable resources supplies, such as fuel cells, photovoltaic cells, wind power and engine generators, for distributed power system have been studied intensely. Conventional compensators with switching devices are constructed based on a voltage source inverter using six arms. Therefore, conventional power quality compensators require a large electrolytic capacitor in the dc link part of the equipment. The use of a large capacitor hinders downsizing efforts and the lowering of equipment costs.
Direct converters, which do not have a large electrolytic capacitor and an initial charge circuit, can be used to realize downsizing and lowering of equipment costs, when compared with conventional converters.
This paper proposes one of new applications of a matrix converter to a PM generator for power quality compensation, such as reactive power compensation, harmonic current and power interruption. The novel point of this work is that the matrix converter provides reactive power with harmonic current. Simulated and experimental results confirm that the matrix converter can maintain high performance as same as a conventional active filter and an uninterruptible power supply (UPS).

著者関連情報
© 電気学会 2008