電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
特集論文
コンデンサモータの負荷時電磁振動に及ぼすスロット数組合せおよび斜めスロットの影響
廣塚 功坪井 和男
著者情報
ジャーナル フリー

2009 年 129 巻 11 号 p. 1075-1084

詳細
抄録
The capacitor motor (CRM) is widely used to drive industrial equipments and electric home appliances. Recently, the reduction in the vibration and noise of the CRM has become increasingly important from the standpoint of environmental improvement. However, the electromagnetic vibration of the CRM under load has not been analyzed sufficiently. Therefore, we have studied the electromagnetic vibration of CRM for the purpose of reducing it. In a previous paper, the relationships for a backward magnetic field, the equivalent circuit current, and the vibration of the CRM were clarified. The present paper theoretically and experimentally discusses the effect of the slot combination and skewed slot on the electromagnetic vibration of CRM under load. The primary conclusions are as follows:
(1) In the case of 4-pole and 6-pole CRMs, the dominant electromagnetic vibration of CRMs was theoretically attributed to three types of electromagnetic force waves. Two types of electromagnetic force waves are generated: one wave is generated by the interaction of two forward magnetic fluxes, such as those of a three-phase squirrel-cage induction motor, and the other wave is generated under the influence of a backward magnetic flux.
(2) The characteristics of dominant electromagnetic vibration depending on load and running capacitor were classified theoretically and experimentally into three types based on the characteristics of the electromagnetic force wave and equivalent circuit current.
(3) The influences of magnetic saturation in dominant electromagnetic vibration were verified experimentally and their causes were clarified theoretically in relation to electromagnetic force waves.