電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
論文
逆相電流の直接検出による誘導機の固定子巻線の短絡故障診断法
加藤 利次井上 馨吉田 圭亮
著者情報
ジャーナル フリー

2011 年 131 巻 11 号 p. 1346-1353

詳細
抄録
In an AC motor, the quick detection of an initially small fault is important for preventing any consequent large fault. Various detection approaches have been proposed in previous papers, for example, by the Park vector (PV), AI techniques, wavelet analysis, and negative-sequence analysis. This paper proposes a method for diagnosing the stator-winding faults of an induction motor by the direct detection of its negative-sequence current. Before starting the diagnosis, the asymmetry admittances for the considered fault cases are obtained by analysis or simulation. The amplitude and phase of the positive-sequence voltage, Vp, and of the positive-sequence current, Ip, are extracted from the voltage PV and current PV, respectively. The amplitude and phase of the negative-sequence, In, are extracted from the residue. The asymmetry admittance, Ya, is calculated from In and Vp. When the positive-sequence admittance is known, Ya can also be calculated from Yp, Ip, and In. These steps are repeated for each sample time and the motor condition is diagnosed according to the variations in the Ya values. The simulation and experimental results are also shown and the proposed method is investigated and validated.
著者関連情報
© 電気学会 2011