電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
論文
可変デッドタイム制御によるソフトスイッチングインバータの低出力域での高効率化
星 伸一松井 綾花
著者情報
ジャーナル フリー

2011 年 131 巻 5 号 p. 679-684

詳細
抄録
The power conversion efficiency of soft-switching inverter can be improved by using loss-less snubber commutation; however, the main switches of the inverter fail in zero-voltage turn-on when the output current is small. As a solution to this problem, adjustable dead time control that involves adjusting the dead time in a loss-less snubber commutation according to the magnitude of output current has been proposed. Adjustable dead time control achieves zero-voltage turn-on of the main switches of the inverter in a loss-less snubber commutation in the range of low output current; however, the inverter output current waveform is distorted. In this paper, we propose a scheme for adjustable dead time control with dead time compensation for soft-switching inverters. Moreover, the effectiveness of the proposed control scheme is verified by performing experiments. The results of the experiments reveal that when the proposed control scheme is adopted, the power conversion efficiency in the range of low output power improves up to about 3% and the THD is improved within 3%.
著者関連情報
© 電気学会 2011
前の記事 次の記事
feedback
Top