抄録
This paper deals with the shaft end-to-end voltage resulting from asymmetric stray capacitances in an inverter-driven motor. The origin of the voltage can be any of the following: a ground leakage current, dielectric breakdown in bearings, and asymmetric stray capacitances on stator windings. The third origin seems to be related to the differential-mode current, but the details of the relationship have not been clarified. In this study, differential-mode tests are carried out on an ungrounded motor rated at 400V and 15kW, and the shaft end-to-end voltage generation by the asymmetric stray capacitances is theoretically discussed. Finaly, a winding model is presented for the purpose of understanding the mechanism responsible for the shaft end-to-end voltage.