電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
論文
三相インバータのレグ間キャパシタ電流アンバランスとその抑制法
平尾 高志和田 圭二清水 敏久
著者情報
ジャーナル フリー

2018 年 138 巻 6 号 p. 491-498

詳細
抄録

This paper proposes a method to suppress the capacitor current imbalance between the phase legs of a three-phase inverter circuit. This circuit consists of half-bridge modules and DC-link capacitors closely connected to each module. It can be designed for low stray inductance between power semiconductor devices and DC-link capacitors in each module. However, in the conventional structure, the stray inductance between the phase legs may lead to an imbalance in the capacitor current due to the DC-side resonance phenomenon under a higher switching frequency condition by using a SiC MOSFET. This paper presents the analyses of the equivalent circuit considering the circuit configuration, which suggests that capacitor current imbalance occurs depending on the stray inductance between phase legs. To suppress the capacitor current imbalance, a delta-type bus bar connecting phase legs is proposed. The experiment results at 300V and 4.6A demonstrate the suppression effectiveness of the proposed method.

著者関連情報
© 2018 電気学会
前の記事 次の記事
feedback
Top