2019 年 139 巻 2 号 p. 136-142
In this study, we developed a current sensorless voltage driven magnetic levitation system with a Hall element displacement sensor using Kalman filter. The system costs less and has higher portability than the current driven system developed in a previous study, and is utilized effectively for model-based development education. However, the use of the displacement sensor for a voltage driven magnetic levitation system causes two problems, namely compensation for measurement error and correction of Hall element output voltages in the sensor. Therefore, we have proposed compensation and correction methods using Kalman filter. To verify the validity of the proposed methods, a magnetic levitation control experiment with the developed system was conducted.