電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
超電導発電機の突発短絡故障時における電気的過渡特性の構造パラメータによる簡易表現
中島 健太木村 友孝白井 康之仁田 旦三
著者情報
ジャーナル フリー

2000 年 120 巻 1 号 p. 38-47

詳細
抄録
Superconducting generators (SCGs) have many advantages as compared with conventional ones, and practical use is expected. Before practical use, it is necessary and important to have a good grasp of the electrical characteristics of SCG under short-circuit conditions. And it is desirable that, relations between characteristics and structure-parameters of generators are explicitly and simply expressed. We obtained transient characteristics of armature current and field current for SCG by use of mathematical electro-magnetic field analyses, and studied relations between characteristics and structure-parameters of machines. In this paper, the method of solution is explained for the sudden line-to-neutral short-circuits, while only the results are quoted for the line-to-line, and the doubleline-to-neutral short-circuits. Comparisons between analytical and experimental, using 20kVA SCG, results were also studied. Consequently, the parameters that dominate the amplitude of transient current were clarified. Besides that, close agreements between analytical and experimental results were obtained.