Dielectric Breakdown Characteristics of Oil-pressboard Insulation System against AC/DC Superposed Voltage
Yoshihito EbisawaShin YamadaShigekazu MoriMasami Ikeda
Author information
JOURNAL FREE ACCESS

2003 Volume 123 Issue 10 Pages 1215-1221

Details
Abstract
This paper describes breakdown characteristics of an oil-pressboard insulation system to a superposition voltage of AC and DC voltages. Although AC electric field is decided by the ratio of the relative permittivity of a pressboard and insulating oil, DC electric field is decided by ratio α of volume resistivities. From the measurement in this study, 13—78 and 1.8—5.7 are obtained as the volume resistivity ratios α at temperature of 30°C and 80°C, respectively. The breakdown voltages against AC, DC, and those superposition voltages are surveyed to insulation models. In normal temperature, the breakdown voltage to the superposition voltage of AC and DC is determined by AC electric field applied to the oil duct. Since the α becomes as low as 2-3 at temperature of 80°C, AC and DC voltages almost equally contribute to the electric field of the oil duct as a result. That is, it became clear that superposed DC voltage boosts the electric field across oil ducts at operating high temperature.
Content from these authors
© 2003 by the Institute of Electrical Engineers of Japan
Previous article Next article