Abstract
This paper describes the effect of mutual leakage reactance in rotor circuit (Canay reactance) on analysis of generator transient characteristics. The authors derived a detailed equivalent circuit model for synchronous generator, and analyzed out-of-phase synchronizing phenomena (synchronizing with phase difference) of the generator by simulations using the electromagnetic transients program (ATP-EMTP), and compared the results with the experimental data.