IEEJ Transactions on Power and Energy
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
Paper
Stability of Step-Response Parameters of Standard Impulse Voltage Divider for Lightning Impulse
Satoru MiyazakiHisashi GoshimaHiroyuki ShinkaiMasafumi YashimaTakayuki WakimotoMasaru Ishii
Author information
JOURNAL FREE ACCESS

2009 Volume 129 Issue 7 Pages 941-947

Details
Abstract
Long-term stability of step-response parameters of the standard voltage divider may be useful in evaluating the long-term stability of the standard measuring system for high voltage impulse, which influences the uncertainty of the system . Because dispersions of the step-response parameters have been large, they have not been considered in evaluating the uncertainty of the system. Dispersion of the experimental response time is largely due to noise superimposed on measured step-response waveforms. It can be reduced either by increasing sampling rates of the waveform or by improving the signal to noise (S/N) ratio. Dispersion of the partial response times is due to oscillations on the wavefront of step-response waveforms. Calculation of the virtual origin becomes unstable in the presence of the oscillation, resulting in the dispersion of the partial response time.
Content from these authors
© 2009 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback