Verification of Effect of Damper Windings on the Transient Condition of Synchronous Generator
Junya MatsukiHisao TaokaYasuhiro HayashiShigeru IwamotoAkihiro Daikoku
Author information
JOURNAL FREE ACCESS

2011 Volume 131 Issue 5 Pages 447-454

Details
Abstract
This paper describes the results of experimental investigation on the effects of damper winding of a 4-pole synchronous generator at the synchronous generator transient. It is known in the simulation that the damper winding acts effectively at the synchronous generator transient condition. However, experimental proof has not been performed yet. Then, experiments on damper effects were conducted in this paper using a laboratory-scale power system. The damper winding of tested generator consists of 5 damper bars each pole and the number of working damper bars can be changed manually. Damper currents at each bar were measured by a Rogowski coil. FFT analysis was applied to both damper currents and armature currents under different operating conditions. Relationships between damper currents in the rotor and armature currents in the stator were made clearer than before.
Content from these authors
© 2011 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback