Abstract
Faraday current, which flows in a circumferential direction in a disk MHD generator, was successfully measured using a method of Rogowski coil. This fact allowed us to estimate the radial distributions of fluid and elecrical propreties, such as gas flow velocity, Hall parameter, electrical conductivity, from the experimental data.