The paper deals with the method of insulation design for reactor tap windings. Surges entering a reactor cause resonance voltages in reactor windings and overvoltages appear between tap windings. New design method for evaluation of overvoltages is experimentally confirmed. We are applied this method to AC SOOkV filter reactor.
A member of IEEJ can access the transactions of the Technical Society to which the member belongs. Please enter the My Page login ID in the subscriber number column and the birth date (year/month/date with one-byte characters: for example, 19800303) in the password column.