Abstract
Damage of piping in geothermal plants is becoming a major issue in the industry. Therefore,we are investigating a system to detect flaws on cracked piping and mineral deposit face by using impact sensor. This paper confirmed that impact sensor output signals vary depending upon artificial deposit amount by using impact sensor.