Usefulness of the Snare Technique During Leadless Pacemaker Implantation for a Patient with a Severely Dilated Right Atrium
A Case Report
Takatsugu HiramatsuYoshiaki MizutaniSatoshi YanagisawaTomomi SugiyamaDaiki YamashitaAtomu TajimaJun YonekawaYuichiro MakinoHitomi SuzukiHitoshi IchimiyaYasuhiro UchidaJunji WatanabeMasaaki KanashiroYasuya IndenToyoaki Murohara
Author information
JOURNAL FREE ACCESS

2022 Volume 63 Issue 1 Pages 159-162

Details
Abstract

We report here the case of a 92-year-old woman with atrial fibrillation bradycardia in which leadless pacemaker implantation was performed with a difficult delivery of the catheter sheath due to an extremely large right atrium. Using a snare technique with correction of the direction of the force on the catheter toward the right ventricle (RV) can result in successful delivery of the pacemaker catheter and stable placement of the pacemaker system in the RV septum. This specific snare technique has the potential to facilitate leadless pacemaker implantation safely in a severely dilated chamber of the heart, making this technique effective to use in clinical practice.