International Heart Journal
Online ISSN : 1349-3299
Print ISSN : 1349-2365
ISSN-L : 1349-2365

This article has now been updated. Please use the final version.

Pulmonary Vein Isolation and Pacemaker Implantation in a Patient with Dextrocardia Situs Inversus
Yasuhiro YokoyamaTakeshi AibaKoji MiyamotoHideaki KanzakiNobuhiko UedaKenzaburo NakajimaTsukasa KamakuraMitsuru WadaKenichiro YamagataKohei IshibashiYuko InoueSatoshi NagaseTakashi NodaChisato IzumiKengo Kusano
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 20-804

Details
Abstract

A 70-year-old female with dextrocardia with situs inversus (DSI) totalis and inferior vena cava occlusion underwent radiofrequency catheter ablation because she had symptomatic paroxysmal atrial fibrillation (AF). Careful preoperative examination made successful pulmonary vein isolation through the left jugular vein approach. One-year later, however, AF recurred, and symptomatic sinus bradycardia or junctional bradycardia often occurred. Then, the pacemaker was implanted. We here reported a rare case of congenital abnormality, DSI with inferior vena cava occlusion who had undergone successful pulmonary vein isolation and pacemaker implantation without any complications.