Japanese Heart Journal
Online ISSN : 1348-673X
Print ISSN : 0021-4868
ISSN-L : 0021-4868
Comparison of Pressure in Lesser Circulation with Left Ventricular Filling Pressure in Patients with Ischemic Heart Disease
Pavel JEBAVÝJaromír RESSLJuraj FABIÁNRuzena JANDOVÁ
著者情報
ジャーナル フリー

1976 年 17 巻 6 号 p. 706-716

詳細
抄録
The left ventricle (LV) was catheterized without X-ray control by a thin teflon catheter introduced through the right brachial artery. Shaping of the catheter allowed entering LV in more than 95% of patients and its safe placement in LV cavity without causing ectopic beats or other complications.
Pressures in the pulmonary circulation (_??_AP, PAPd, PCW) do not reflect left ventricular filling pressure (LVEDP) precisely, particularly when the LVEDP is elevated. The assessment of pathological LV filling pressure from the pulmonary arterial pressures shows, that there was high percentage of false negative results at rest, but during exercise the abnormal values of LVEDP could be predicted from the pulmonary artery pressures. However, PCW or PAPd cannot be considered as identical with LVEDP.
For the rough assessment of apparent left ventricular failure it is sufficient to measure pressures in the pulmonary artery. However, for the exact study, the LV should be catheterized. The described bed-side method fulfill all requirements: it is simple, convenient and safe ; the pressure is recorded accurately ; the procedure can be repeated and is there fore recommended for wider use.
著者関連情報
© by International Heart Journal Association
前の記事 次の記事
feedback
Top