Abstract
Aerating hydroturbines have recently been proposed as an effective way to mitigate the problem of low
dissolved oxygen in the discharge of hydroelectric power plants. The design of such a hydroturbine
requires a precise understanding of the dependence of the generated bubble size distribution upon the
operating conditions (viz. liquid velocity, air ventilation rate, hydrofoil configuration, etc.) and the
consequent rise in dissolved oxygen in the downstream water. The purpose of the current research is to
investigate the effect of location of air injection on the resulting bubble size distribution, thus leading to a
quantitative analysis of aeration statistics and capabilities for two turbine blade hydrofoil designs. The two
blade designs differed in their location of air injection. Extensive sets of experiments were conducted by
varying the liquid velocity, aeration rate and the hydrofoil angle of attack, to characterize the resulting
bubble size distribution. Using a shadow imaging technique to capture the bubble images in the wake and
an in-house developed image analysis algorithm, it was found that the hydrofoil with leading edge
ventilation produced smaller size bubbles as compared to the hydrofoil being ventilated at the trailing edge.
© 2015 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR