鋳物
Online ISSN : 2186-0335
Print ISSN : 0021-4396
ISSN-L : 0021-4396
研究論文
コンパクテド・バーミキュラー黒鉛鋳鉄の温度伝導率測定について
斉藤 図田中 雄一戸倉 郁夫井川 克也
著者情報
ジャーナル フリー

1981 年 53 巻 3 号 p. 112-116

詳細
抄録
  A new method using a relatively short cylindrical bar as a test piece was proposed for measurement of thermal diffusivity of some cast irons, and the theoretical treatment and the reliability and accuracy of the method were discussed. Also, heat transfer coefficient on the surface of a test piece and the temperature difference between the initial and the final states of the test piece were found from the experiment to be small in their influence on the measured results. Furthermore, the thermal diffusivity of cast irons was measured and tabulated as a function of spheroidicity, showing that the so-called compacted-vermicular graphite cast iron was much closer to the flake graphite rather than to the spheroidal graphite cast iron in its heat transfer characteristics at around 300°C.
著者関連情報
© 1981 公益社団法人 日本鋳造工学会
前の記事 次の記事
feedback