Internal Medicine
Online ISSN : 1349-7235
Print ISSN : 0918-2918
ISSN-L : 0918-2918
CASE REPORTS
Type III Endoleak of a Disconnected Stent-graft Limb
Yusuke OchiumiYoriyasu SuzukiYasuhiro Oba
Author information
JOURNAL OPEN ACCESS

2017 Volume 56 Issue 18 Pages 2441-2443

Details
Abstract

A 70-year-old man, who had undergone the placement of an endovascular aneurysm repair graft for an abdominal aortic aneurysm 7 years previously, presented to our facility with the separation of a left iliac stent-graft limb from the main-body stent-graft, resulting in a type III endoleak. An attempt was made to repair the disconnected stent-graft limb with endovascular intervention. An extension stent-graft was successfully deployed using a pulled-through technique to connect the main-body stent-graft with the disconnected stent-graft limb. Endovascular intervention may be an acceptable treatment for type III endoleaks.