システム制御情報学会論文誌
Online ISSN : 2185-811X
Print ISSN : 1342-5668
ISSN-L : 1342-5668
二重構造適応観測器のロバスト性
李 勇米澤 洋西村 行雄
著者情報
ジャーナル フリー

1992 年 5 巻 12 号 p. 507-512

詳細
抄録

The usual process identification methods for parameter adjustment, along with dead zone, are effective in providing a robust adaptive observer of an unknown plant under uncertain input disturbance and output measurement noise. But it is difficult to decide the size of the dead zone due to the lack of knowledge concerning the disturbance. Furthermore, an error may remain in the dead zone despite the existence or nonexistence of the disturbance and the noise. In this paper, we propose a double-adaptive observer and discuss its robustness. Unlike previous work, this scheme does not introduce parameters that depend on the characteristics of the unknown disturbance. So, when the disturbance or the noise does not exist, the parameters converge over time. The stability of the system is discussed and computer simulation results are presented.

著者関連情報
© システム制御情報学会
前の記事 次の記事
feedback
Top