Proceedings of the JFPS International Symposium on Fluid Power
Online ISSN : 2185-6303
ISSN-L : 2185-6303
RESEARCH ON CALCULATION METHOD O TANK'S LEAKAGE FLOW RATE BY DIFFERENTIAL PRESSURE COMPARISON
Tao WangGuang Zheng PengTong ZhaoShinichi HOMMA
著者情報
ジャーナル フリー

2002 年 2002 巻 5-1 号 p. 79-82

詳細
抄録

By measuring the variation of differential pressure between a master tank (without leakage) and a measured tank (with leakage), leakage flow rate of the measured tank can be calculated.
In this research a new calculation method is studied for measuring air leakage flow rate. Based on the law of air flow through a leakage hole, the theoretical formula of the leakage flow rate which has unacquainted parameters is got. By using statistics method, the unacquainted parameters in the mathematic model of the differential pressure, namely the unacquainted parameters in the theoretically formula of leakage flow can be estimated by differential pressure from experiment. Thereby leakage flow can be calculated and the error of leakage flow can also be determined. Compared with mass flow meter as standard measurement, the accuracy of leakage flow rate by the new method is higher than by the traditional method.

著者関連情報
© The Japan Fluid Power System Society
前の記事 次の記事
feedback