ISIJ International
Online ISSN : 1347-5460
Print ISSN : 0915-1559
ISSN-L : 0915-1559
Note
Numerical Simulation of Cooling Process after Hot Rolling with Realistic Residual Water Levels
Myeon Jae KwonIl Seouk Park
著者情報
ジャーナル オープンアクセス HTML

2015 年 55 巻 8 号 p. 1791-1793

詳細
抄録

The cooling process of a moving hot steel plate after hot rolling was numerically investigated. Many important parameters affect the cooling process. This study focuses on residual water, which accumulates on the surface of the moving plate by the continuous supply of cooling water. This residual water may significantly interfere with the impingement of water jets and the cooling of the steel plate. In this study, we devised a concept of artificial sidewalls to apply a realistic residual water level in a numerical simulation of a cooling hot steel plate. The necessity for this concept of an artificial sidewall for simulations of moving plate cooling was investigated by comparing the cooling history of the plate for three different longitudinal domain cases with and without artificial sidewalls.

著者関連情報
© 2015 by The Iron and Steel Institute of Japan
前の記事 次の記事
feedback
Top