New Calibration Technique for X-ray Absorption Studies in Single and Multiphase Flows in Packed Bed
M. G. BasavarajG. S. Gupta
著者情報
ジャーナル オープンアクセス

2004 年 44 巻 1 号 p. 50-58

詳細
抄録
An X-ray technique has been developed to determine the concentration and liquid holdup in a packed bed. To quantify these parameters in single and multiphase flow systems, at local level, a calibration method/graph has been developed. This graph has also been used to obtain the local concentration value of a liquid in presence/absence of another miscible liquid in a porous media. The same graph has been used to quantify the local liquid holdups (static and dynamic) in a packed bed. The same technique can be used for other radiological methods such as gamma rays and neutron radiography. Results obtained from this technique are in agreement with the published data.