ISIJ International
Online ISSN : 1347-5460
Print ISSN : 0915-1559
ISSN-L : 0915-1559
Nitrogen Oxides (NOx) Formation and Control in an Electric Arc Furnace (EAF): Analysis with Measurements and Computational Fluid Dynamics (CFD) Modeling
E. ChanM. RileyM. J. ThomsonE. J. Evenson
著者情報
キーワード: NOx, CFD, modeling, EAF, pollution control
ジャーナル フリー

2004 年 44 巻 2 号 p. 429-438

詳細
抄録

A computational fluid dynamics (CFD) model of an electric arc furnace (EAF) has been developed and validated against measurements at the EAF combustion gap. Modeled processes include fluid flow, combustion reactions, radiative heat transfer, turbulence, and NOx formation. This model is used to identify the NOx formation mechanisms and to analyse potential NOx control strategies.
The model successfully predicts the NOx emission trends. NOx formation is primarily due to N2 from air ingress through the slag door or roof ring gap, flowing into the high temperature regions near the burners. N2 in the oxygen supply is also important. NOx levels correlate with N2 and O2 levels in the furnace. Reducing N2 and excess O2 in the furnace is recommended for NOx abatement. Unlike many combustion devices, controlling temperature is not recommended for reducing NOx emissions. Large reductions in NOx emissions are predicted by (in order of importance, from highest to lowest): controlling exhaust flows to limit air ingress, closing the slag door and increasing the purity of the oxygen supply.

著者関連情報
© The Iron and Steel Institute of Japan
前の記事 次の記事