LASER THERAPY
Online ISSN : 1884-7269
Print ISSN : 0898-5901
ISSN-L : 0898-5901
Original Article
Escherichia coli Sterilization Using a Light-Emitting Diode and Methylene Blue
E. coli sterilization by LED and MB
Kouji Ogasawara Susumu NakajimaHiroshi SatoTadashi Sasaki
著者情報
ジャーナル フリー

2019 年 28 巻 2 号 p. 97-102

詳細
抄録

Background and aims: The prevalence of pathogenic Escherichia coli as well as E. coli O157 and antibiotic-resistant bacteria has increased. This study aimed to examine the effect of methylene blue (MB) with sodium bicarbonate (NaHCO3) against E. coli using photodynamic antimicrobial chemotherapy (PACT).
Materials and methods: MB was basified using NaHCO3. E. coli and basic MB were smeared on the culture media followed by irradiation using a red light-emitting diode (LED) at 660 nm. Energy densities of 5, 10, 15, and 20 J/cm2 were applied to the culture medium.
After 24 h, the bactericidal effect of basic MB with LED irradiation was determined based on the bacterial growth.
Results: The basic effect was observed with 1%–6% of NaHCO3 at 5 J/cm2. This effect increased between 1% and 2% of NaHCO3 at 10 J/cm2 and 15 J/cm2, whereas decreased at the NaHCO3 concentrations of > 2%. Moreover, this effect decreased at an energy density of 20 J/cm2. The biphasic basic effect on bactericidal activity was observed between pH 8.6 – 9.0.
Conclusions: Thus, PACT using basic MB may be an effective method for pathogenic E. coli sterilization.

著者関連情報
© 2019 Japan Medical Laser Laboratory