ITE Technical Report
Online ISSN : 2424-1970
Print ISSN : 1342-6893
ISSN-L : 1342-6893
22.36
Conference information
Excited atoms density measurements in a discharge cell of AC PDP by using microscopic-spectroscopy
T. TanakaK. ItoE. NagasakaT. SakaiS. FengT. Tachibana
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 13-18

Details
Abstract
Xe metastable atom densities in an AC PDP cell are measured in the sustain mode by laser spectro-microscopy. It has been found that : (1) The peak density at the cathode side is nearly equal to the density at the anode side, (2) The density at the center is about 1/3 of the value at the cathode side, (3) The rise time of the density is 0.2μs with a delay of about 0.2-0.3μs. The decay time is 3μs at cathode side, and 1.8μs at anode side, respectively, which agree with an estimated value of 3.1 μs, (4) In the sustain mode AC PDP operates with pulse memory function like as DC PDP.
Content from these authors
© 1998 The Institute of Image Information and Television Engineers
Previous article Next article
feedback