Journal of Asian Architecture and Building Engineering
Online ISSN : 1347-2852
Print ISSN : 1346-7581
Environmental Engineering
Thermal Performance Evaluation of Large-span Roofs with Ventilating Cavity in Hot Climates: Case Study of Shenzhen Railway Station Hall
Yuan LeiShao LiliXu Xuesong
著者情報
ジャーナル フリー

2015 年 14 巻 2 号 p. 491-498

詳細
抄録
Roofs of large-span structures always cause severe building energy consumption as well as uncomfortable indoor environments, especially in hot climates. This paper presents the evaluation of a passive roof structure which is designed to significantly reduce roof heat conduction and consequently improve interior comfort. With its ventilating cavity, this roof structure can remove the residual heat between its outer and inner layers. As a case study, the recently built Shenzhen railway station hall and on-site measurement is used for method validation. 3D steady Computational Fluid Dynamics (CFD) simulations, as well as energy consumption simulations, of roof form comparison have been conducted under different conditions. The cross comparison shows that this structure is effective in providing a climatic buffer against hot weather and consequently reduces the enormous energy consumption in large-span structures.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2015 Architectural Institute of Japan
前の記事
feedback
Top