Journal of Asian Architecture and Building Engineering
Online ISSN : 1347-2852
Print ISSN : 1346-7581
Environmental Engineering
A Study on External Shading Devices for Reducing Cooling Loads and Improving Daylighting in Office Buildings
Kim MinseokLeigh Seung-BokKim TaeyeonCho Sooyoun
著者情報
ジャーナル フリー

2015 年 14 巻 3 号 p. 687-694

詳細
抄録
This study is aimed at analyzing the impact of effective shading design for office buildings. For shade design, the overheated period for the area in which a target building was located was estimated, the building was configured to be shaded during this period, and a different shading design was applied for each direction. Using this shade design, the daylighting performance and the reduction in cooling loads during the overheated period were evaluated. The daylighting performance was evaluated by employing the daylight factor and useful daylight illuminance (UDI). The results showed a 35% reduction in cooling loads due to the shading device. Regarding the daylight factor, more points were included in a proper daylight factor of 2–5%, which was shown to increase the UDI to 500–2,000 lux.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2015 Architectural Institute of Japan
前の記事 次の記事
feedback