Journal of Asian Architecture and Building Engineering
Online ISSN : 1347-2852
Print ISSN : 1346-7581
Environmental Engineering
Development of Thermoelectric Heat Pump Water Heaters
Qing-hai LuoGuang-fa TangNian-ping Li
著者情報
ジャーナル フリー

2005 年 4 巻 1 号 p. 217-222

詳細
抄録
Experiments verified that a thermoelectric heat pump system is more efficient than an electrical heating device, for its heating coefficient reached more than 1.6 with suitable operating conditions. Two novel instantaneous water heaters were developed and tested successively. The prototype with circulating water pump can save power consumption more than 40% in comparison with conventional electric water heaters, while the prototype integrating with thermosiphon can save more than 38%. Comparing two prototypes, the latter prototype becomes more compact, more technologically advanced and practical, because it eliminated the working life choke-point of the former, while holding the advantages, such as high efficiency, reliability, safety, environmental friendly.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2005 Architectural Institute of Japan
前の記事 次の記事
feedback
Top