空気清浄-コンタミネーションコントロール
Online ISSN : 2759-9922
Print ISSN : 0023-5032
二酸化塩素ガスによる除染について
【特集】 除染と環境制御
荒川 宏樹高橋 秀人
著者情報
解説誌・一般情報誌 フリー

2022 年 60 巻 2 号 p. 79-87

詳細
抄録
The sterilization ability of the chlorine dioxide( ClO₂) gas, which has been used as an alternative decontamination agent of carcinogenic formaldehyde gas, is investigated. The validity of the sterilization condition based on a 60 m3 actual production line of clinical experimental medicine is evaluated. As the result, all of the 42 BIs (biological indicators) in the production line were negative. In addition, the fast and reliable decision protocol by a Micro Colony-ATP (Adenosine Triphosphate) method as an alternative method to the culture and measurement method( gas measurement method, plate culture method)of BI bacteria, which took several days to several weeks for decontamination judgment is devised and validated. As the result, we confirmed that the judging decontamination effect was possible within 12 hours. The combination of chlorine dioxide gas decontamination and the Micro Colony - ATP method can further increase the convenience of users of decontaminated facilities because the decontamination judgment result can be confirmed, and the operation can be started by the next morning after the decontamination work.
著者関連情報
© 2022 公益社団法人日本空気清浄協会
前の記事 次の記事
feedback
Top