日本原子力学会誌
Online ISSN : 2186-5256
Print ISSN : 0004-7120
ISSN-L : 0004-7120
148. 高速増殖炉原子炉建物の地震荷重低減
奈良 義彦阿部 康宏後藤 義則毛呂 達山口 友久
著者情報
ジャーナル フリー

1987 年 29 巻 1 号 p. 48-57

詳細
抄録

In the course of the development of the commercial Liquid Metal Fast Breeder Reactor (LMFBR), the mitigation of seismic load on building and components should be performed. This is required not only from the standpoint of compatibility of seismic design and high-temperature structural design, but also effective for cost reduction of the plant.
We studied following two schemes on the reactor building of 1, 000MWe loop type LMFBR:
(1) Application of seismic isolation
(2) Estimation of effects of building embedment.
The results showed that above two schemes were effective to mitigate the seismic load of reactor building and component.

著者関連情報
© by the Atomic Energy Society of Japan