1988 年 30 巻 6 号 p. 531-538
At the Tokai Research Establishment of Japan Atomic Energy Research Institute, the radioactive solid waste incineration unit with a capacity of 100 kg/h was installed in 1979, since then the unit has been routinly operated. An off-gas cleaning system of the unit consists mainly of a primary and secondary ceramic filters, a heat resistant HEPA filter and a scrubber. A series of hot test was carried out to examine the decontamination performance for radionuclides in the off-gas cleaning system. In the test, simulated wastes contaminated with a known quantity of radionuclides were burned in the unit, and radioactive concentrations in the off-gas were measured. And then, the following data were obtained: a retention factor of radionuclides in a furnace and a decontamination factor for radionuclides in each of off-gas cleaning components. And also overall decontamination factors, defined as the ratio of radioactivities input to the furnace to radioactivities passed through outlet of the HEPA filter, were 9×106(2×107) or more for 58Co (60Co), 1×102 for 75Se, 4×104 for 106Ru and 1×108 or more for 134Cs.