日本法科学技術学会誌
Online ISSN : 1881-4689
Print ISSN : 1880-1323
ISSN-L : 1880-1323
技術報告
改重回帰分析法を用いる灯油の燃焼残さの識別
肥田 宗政佐藤 弘康奥山 修司三井 利幸
著者情報
ジャーナル フリー

2008 年 13 巻 1 号 p. 59-66

詳細
抄録
  Sixty-one liquid kerosene samples and extracts from seventy-nine fire debris were calculated from multiple correlation coefficients (R) against two kinds of marketing kerosene as reference with a different calculation method of regression analysis by using 16 components that was eluted after n-undecane. Quantitative evaluation for debris of kerosene was performed with the R values. If the sample R value obtained was more than 0.95 using a gas chromatogram, we can judge the sample to be kerosene. For the sample R values from 0.95 to 0.85, additional information was required to judge the samples of kerosene. If the sample R value showed less than 0.85, it can be concluded that it was not kerosene.
著者関連情報
© 2008 日本法科学技術学会