ガスレンジおよびIHヒータで加熱した沸騰水からのミスト発生状況の違いに関する検討
諏訪 好英鍵 直樹並木 則和
著者情報
ジャーナル フリー

2009 年 24 巻 4 号 p. 262-267

詳細
抄録

Temperature and airflow distributions around heated pans by a gas-oven and an IH-heater were compared, and the difference in steam generation was studied. As a result, we found that the existence of flame around a pan affected the airflow and the temperature distribution, etc. We also found that water evaporated by IH-heaters was more easily changed into mist.
The number concentration and the size distribution of water mist were measured using a PDPA system. The number of water mist generated with the IH-heater was 10 to 100 times larger than the number of mist generated with the gas-oven. The mode diameter of mist generated with the IH-heater was 8 to 10 μm, and that with gas-oven was 4 to 5 μm. We concluded that the mist size difference resulted from the difference in temperature distribution and the existence of hot flame around the pan in the case of gas-oven.