大気エアロゾル化学成分連続自動分析装置(ACSA-12)とデニューダー・フィルター法による大気エアロゾル粒子の粒径別イオン成分濃度の比較
長田 和雄上口 友輔山本 重一桑原 昇平Pan Xiaole原 由香里鵜野 伊津志
著者情報
ジャーナル フリー

2016 年 31 巻 3 号 p. 203-209

詳細
抄録

Simultaneous observations of ionic constituents for size-segregated aerosol particles were conducted at Chikushi Campus of Kyusyu University by using a Continuous Dichotomous Aerosol Chemical Speciation Analyzer (ACSA-12) and a denuder-filter (DF) method from September to December, 2014. For SO42- and NO3-, the sum of fine (<2.5 μm) and coarse (2.5–10 μm) mode concentrations of ACSA-12 correlated well with the DF data. Concentration of ΔH also showed a good correlation with fine mode H from the DF method but insignificant correlation for coarse mode data during the study period. Temporal and seasonal variations of fine mode WSOC concentrations from ACSA-12 were similar to that of fine mode C2O42- concentrations from the DF method. Tendency of covariation for fine mode NO3- concentrations was also found for fine mode WSOC or C2O42- concentrations. Further experiments for WSOC including more realistic calibration is strongly recommended for data validation of ACSA-12.

著者関連情報
© 2016 日本エアロゾル学会