Suctionable Gauze Ball Operated by the Console Surgeon Overcomes Wet Scenes during Robotic Rectal Surgery
Kaori WatanabeHajime UshigomeHiroki TakahashiAkira KatoShinnosuke HarataYoshiaki FujiiTakeshi YanagitaTakuya SuzukiKazuyoshi ShigaRyo OgawaYoichi MatsuoShuji Takiguchi
著者情報
キーワード: robotic surgery, suction, retraction
ジャーナル オープンアクセス

2024 年 8 巻 1 号 p. 43-47

詳細
抄録

Although robotic rectal resections are now widely performed, there are few robotic suction tools that can be easily used by console surgeons. It can therefore be difficult to maintain a clear visual field in the pelvis when there is effusion and bleeding from either a highly advanced cancer or from preoperative cancer treatment. In this report, we introduce our unique surgical technique that uses a soft catheter with a small gauze ball attached, inserted through the assistant port. This simple and inexpensive "instrument" can be used by the console surgeon as a retractor as well as a reliable suction device to secure their view of the operative field in the pelvis. This technique can be used in a narrow surgical field and does not rely on an assistant surgeon, making it potentially applicable to all types of surgery.

Fullsize Image
著者関連情報
© 2024 The Japan Society of Coloproctology

JARC is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. Anyone may download, reuse, copy, reprint, or distribute articles published in the Journal for non-profit purposes if they cite the original authors and source properly. If anyone remixes, transforms, or builds upon the material, you may not distribute the modified material.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事
feedback
Top