航空医学実験隊報告
Online ISSN : 2432-4809
Print ISSN : 0023-2858
C‐130を想定した輸送機内における聴診活動と意思疎通に関する基礎的検討
西 修二石川 誠彦加藤 圭野見山 武徳樽井 英夫村上 宣之
著者情報
研究報告書・技術報告書 オープンアクセス

2007 年 47 巻 3 号 p. 163-170

詳細
抄録
The Japan Air Self-defense Force (JASDF) C-130 cargo aircrafts used to provide aeromedical evacuation are extremely noisy (89 dBA-93 dBA) and this prevents vocal communication and/or auscultation with stethoscope. In 2007, Aero Medical Evacuation Squadron was establishment equipped with a special container for aeromedical evacuation. Then in the simulated noise environment as a C-130 noise, we evaluated amount of the noise reduction and its effect on vocal communication and auscultation. Vocal communication and breath sound auscultation tests were performed by JASDF flight surgeons. As a result, the threshold of noise for the vocal communication and breath sound diagnosis was 80 dBA and 70 dBA, respectively.
著者関連情報
© 2007 航空医学実験隊