THE JOURNAL OF THE ACOUSTICAL SOCIETY OF JAPAN
Online ISSN : 2432-2040
Print ISSN : 0369-4232
Program Time Regulator by Sampling Method
Gen Nishinomiya
Author information
JOURNAL FREE ACCESS

1962 Volume 18 Issue 5 Pages 269-274

Details
Abstract
This paper, describes a program time regulator by sampling method using a revolving head assembly, mainly its principle, mechanism for experiment, problems of head scanning, and the effects by the following factors-sampling width, time constant at sampling boundary, regulating rate, etc. The results clarified by this experiment are as follows: 1)To eliminate echo distortion, reproducing output of each magnetic head must be switched by an electronic circuit. 2)In speech, most suitable sampling width was 30 ms. 3)To Resolve the click and the level fluctuation at the sampling boundary, it was affective to set the switching time constant at 2〜3 ms. 4)In the case of large rate of regulation such as about 100% expansion or 50% compression, too the intelligibility was little destroyed.
Content from these authors
© 1962 Acoustical Society of Japan