日本マイクログラビティ応用学会誌
Print ISSN : 0915-3616
Isotope Distribution in Pure Indium after Liquid-State Centrifugation
Masao ONO Satoru OKAYASUFumitaka ESAKARie HARUKITsutomu MASHIMO
著者情報
ジャーナル オープンアクセス

2011 年 28 巻 2 号 p. 89-

詳細
抄録
An ultracentrifuge experiment was performed on a pure liquid-indium at centrifugal acceleration field of 8.2x105 g at 300℃ for 100 hours. The isotope ratio measurements were performed on the centrifuged specimen, which was cooled and solidified before release the acceleration, with Secondary Ion Mass Spectrometer (CAMECA IMS-6f). 113In/115In isotope ratio on the specimen changed with negative gradient in the direction of centrifugal acceleration approximately 1.4%. The measurement result indicated that the heavy 115In isotopes moved in the direction of the centrifugal acceleration and the light 113In isotopes moved in the counter direction in the specimen.