JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
Original Papers
Effect of Secondary Air Injection on Bed-to-Wall Heat Trasfer in a Circulating Fluidized Bed
Yong Jun ChoWon NamkungSang Done KimSunwon ParkPyung-Tchai Kim
著者情報
ジャーナル フリー

1996 年 29 巻 1 号 p. 44-50

詳細
抄録
The effects of secondary air ratio (0–50%) and injection types (radial or tangential) on the bed-to-wall heat transfer coefficient have been determined in a circulating fluidized bed (0.1 m-I.D. × 5.3 m-high). The bed-to-wall heat transfer coefficient increases with increasing particle suspension density. The heat transfer coefficient by gas convection increases, but the overall convective heat transfer coefficient decreases with increasing the radial injection of secondary air. The convective heat transfer coefficient increases, but the particle convective component decreases with the tangential secondary air injection. A model, based on the model of Basu (1990), is proposed to predict the bed-to-wall heat transfer coefficients in a circulating fluidized bed (CFB) with the tangential secondary air injection system.
著者関連情報
© 1996 The Society of Chemical Engineers, Japan