JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
Separation Engineering
Operability Improvement in a Fully Thermally Coupled Distillation System with Separated Main Columns
Young Han Kim
著者情報
ジャーナル 認証あり

2006 年 39 巻 3 号 p. 284-291

詳細
抄録
For operability improvement in a fully thermally coupled distillation column (FTCDC), a new configuration of a separated main column system was proposed and its performance was examined with an industrial BTX fractionation process. The main column of an original FTCDC was divided into two sections, and the three sections including a prefractionator and the two main columns were operated at different pressures resulting in easy vapor transfer between the sections. The section pressure can be independently manipulated according to product volatility. In addition, the separate adjustment of liquid flow at the sections makes the control of product specification easier than that of the original FTCDC as exhibited in the simulation study of a step response test.
著者関連情報
© 2006 The Society of Chemical Engineers, Japan
前の記事 次の記事
feedback