JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
Ibuprofen Racemate Separation by Simulated Moving Bed
Joon Sup ParkWoo-Sik KimJong Min KimIn-Ho Kim
著者情報
キーワード: SMB, Ibuprofen, Chiral
ジャーナル 認証あり

2008 年 41 巻 7 号 p. 624-626

詳細
抄録
Ibuprofen racemates were separated in a SMB system with 4 chromatographic columns packed with TBB gels. Retention times of R- and S-enantiomers of ibuprofen were measured in batch chromatography experiments with hexane/TBME/acetic acid mixed solvent. Isotherm parameters of SMB were calculated from the batch chromatography data, and operation flow parameters obtained from m2 and m3 plane of Morbidelli and coworkers (Abel et al., 2004). Experimental results are summarized as purities of raffinate. In order to compare experiments with simulations, ASPEN Chromatography Simulator was adopted. Isotherm and operation parameters were inserted to the dialog box of the simulator and output display data was cropped for comparison of experiments and simulations.
著者関連情報
© 2008 The Society of Chemical Engineers, Japan
前の記事 次の記事
feedback
Top