JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
Materials Engineering and Interfacial Phenomena
Reaction Kinetics Study of All cis-Polyaniline Nanotube Film Modified Electrode for Fast Ascorbic Acid Detecting
Xuli MaLianxi SiXiumin LiHaiyan DuXiaogang HaoZhongde Wang Abuliti AbudulaGuoqing Guan
著者情報
ジャーナル 認証あり

2016 年 49 巻 10 号 p. 937-942

詳細
抄録

A reaction kinetics study was performed for all cis-polyaniline nanotube (ACPN) film modified electrode for fast ascorbic acid detecting. An ACPN film modified electrode exhibited excellent electrocatalytic activity, a low detection limit and a high sensitivity to ascorbic acid (AA). It is found that AA can be electro-catalytically oxidized on an ACPN film even at a concentration less than 1 mM. A mechanism of AA electrooxidation on the ACPN film modified electrode was proposed. Furthermore, the detection sensitivity was regulated by tuning the film thickness, and the optimized fabrication conditions for the ACPN film modified electrode was obtained. Based on the reaction kinetics study, the catalytic rate constant for the best electrode was found to be 6.3×106 cm3·mol−1·s−1. It is expected that such a sensor based on the ACPN film can be widely applied for AA detection.

著者関連情報
© 2016 The Society of Chemical Engineers, Japan
前の記事 次の記事
feedback
Top